Busch-Smoke alarm detector ProfessionalLINE

A safe decision.

A fire always occurs unexpected. And very often during the night. Particularly when everyone is asleep do fires in private homes become a deadly hazard, because a persons does not smell anything while asleep. Similar to a dog. That's why it is reassuring to know that a Busch-Smoke alarm detector is keeping watch. With absolute reliability around the clock it wakes everyone in the house at the slightest indication of smoke - loudly and in time.

The Busch-Smoke alarm detector ProfessionalLINE is available in different versions. The following functions are integrated, depending on the model:

  • Battery permanently installed (sealed-in) with a service life of ten years
  • Sufficient battery capacity for a weekly function test by the user
  • Battery cannot be removed for other purposes
  • No incorrect insertion of battery possible
  • Battery service life = for the full use of the smoke detector
  • Smoke chamber has contamination compensation and protection against insects
  • Smoke chamber is antistatic to prevent dust from being attracted.
  • Q-Label (extended text according to VdS 3131)
  • European product standard EN 14604
  • German application standard DIN 14676
  • Mounting via universal fixture, compatible drill holes
  • Dismantling safety
  • Test every 16 seconds, without display, suitable for bedrooms
  • Mute function can be activated for ten minutes
  • Slowly increasing alarm sound during function test

Optimum protection with networking.

A protective network for your safety. The best smoke alarm over several floors in houses and apartments is useless if it cannot be heard. If it is too far away. To this we object: with smoke and heat detectors that are easy to network. They provide safety from the cellar to the roof. Whether wired or radio controlled: if one detector recognizes a danger, all installed devices alert the residents immediately - irrespective of where the smoke is located. This increases safety enormously, especially at night if not all rooms are being used.

A connection to external systems such as vibrating pillows for the blind or light signal devices for the deaf, but also to KNX is possible at all times via the Busch-Smoke alarm detector relay.

Also in case of radio controlled networking, each single alarm unit is directly connected with all the others. If this is not possible for structural reasons, the next detector retransmits the radio signal (repeater function). The triggering smoke or heat alarm differs from the other devices in the house by means of a flashing alarm light. It is a safe network for your protection, because thanks to the lithium batteries that are permanently installed in the radio control module and which have a service life of ten years, the full functionality is of the networked alarm units is assured even during a mains power failure.


Smoke alarm detector correctly positioned. Examples for planning.


Example 1 - One-family house.

Installation in all bedrooms:

  • Bedroom
  • Children's room


Installation in escape routes:

  • Hallway



Example 2 – One-family house.

Installation in all bedrooms:

  • Bedroom
  • Children's room 1
  • Children's room 2


Installation in escape routes:

  • Hallway



Example 3 – Apartments with U-shaped hallway.

Installation in all bedrooms:

  • Bedroom
  • Children's room 1
  • Children's room 2


Installation in escape routes:

  • Hallway: In crossways, entry areas and corners
    (mitred lines) of hallways one detector
    is to be set up in each